商品編號: Belden-29500
Belden-29500 Awg16 3C with Foil/Braid Shield- 1000V UL Flexible Motor Supply Cable(柔性變頻馬達驅動控制電纜)
Multi-Conductor - 1000V UL Flexible Motor Supply Cable
4-cond. (3) stranded tinned copper circuit conductors, (1) ground wire with PVC insulation, XLPE insulation, Overall Duofoil® (100% coverage) plus a tinned copper braid shield (85% coverage) , tinned copper drain wire, Oil & Sun-resistant PVC jacket.
Usage (Overall)
Suitable Applications: |
AC Motor Drives, VFD, Variable Frequency Drive (變頻馬達驅動控制線) |
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors |
AWG |
Stranding |
Conductor Material |
3 |
16 |
26x30 |
TC - Tinned Copper |
|
Ground Wire
Ground Wire Stranding: |
26x30 |
Ground Wire Conductor Material: |
TC - Tinned Copper |
Ground Wire Insulation Material: |
PVC - Polyvinyl Chloride |
Insulation
Insulation Material:
Insulation Material |
Wall Thickness (in.) |
XLPE - Cross Linked Polyethylene |
.045 |
|
Insulation Resistance: |
300 Megaohms/1000 ft. |
Outer Shield
Outer Shield Material:
Layer # |
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
1 |
Duofoil® |
Tape |
Aluminum Foil-Polyester Tape |
100 |
2 |
|
Braid |
TC - Tinned Copper |
85 |
|
Outer Shield Drain Wire AWG:
AWG |
Stranding |
Drain Wire Conductor Material |
16 |
26x30 |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
PVC - Polyvinyl Chloride |
|
Overall Cabling
Overall Nominal Diameter: |
0.530 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-40°C To +90°C Dry, +90°C Wet |
UL Temperature Rating: |
90°C Wet/Dry |
Bulk Cable Weight: |
160 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
128 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
4.250 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
RHW-2 Type, TC-ER, Unlisted Singles, WTTC |
CSA Specification: |
1000 V AWM I/II A/B |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
10/13/2005 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
PMSHA Specification: |
P-07-KA070003 |
Other Specification: |
1000V UL Flexible Motor Supply Cable |
Flame Test
UL Flame Test: |
UL1685 UL Loading |
IEEE Flame Test: |
1202, IEEE 383 Vertical Tray Flame Test (70,000 BTU) |
Suitability
Suitability - Indoor: |
Yes |
Suitability - Outdoor: |
Yes |
Suitability - Burial: |
Yes |
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
4.0 |
|
Max. Operating Voltage - UL:
Voltage |
1000 V RMS (Flexible Motor Supply Cable) |
600 V RMS (NEC Type TC) |
|
Max. Recommended Current:
Current |
18 Amps per conductor @ 25°C |
|
keyword: YEIDA, 宜大電線, google, gmail, wikipedia, 維基百科, 工業自動化, 電動馬達, 東元電機, ABB, 西門子,
Belden-29500 Awg16 3C with Foil/Braid Shield- 1000V UL Flexible Motor Supply Cable(柔性變頻馬達驅動控制電纜),
Belden29500, Belden29501, Belden29502, Belden29503, Belden29504, Belden29505, Belden29506, Belden29507, |