DESCRIPTION:
22 AWG stranded tinned copper conductors, PVC insulation (power), FPE insulation (data), each pair individually Beldfoil® shielded (100% coverage), PVC jacket
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Pairs: 2
Total Number of Conductors: 4
AWG:
Number of Pairs AWG Stranding Conductor Material Conductor Diameter (in.)
2 22 19x34 TC - Tinned Copper .030
Stranding: 19x34
Conductor Diameter: .030 in.
Conductor Material: TC - Tinned Copper
INSULATION :
Insulation Material: PVC - Polyvinyl Chloride, FPE - Foam Polyethylene
Insulation Material (Multi-AWG):
AWG Layer Number Material Trade Name Material Wall Thickness (in.) Diameter (in.)
22 AWG (Power Pair) PVC - Polyvinyl Chloride
22 AWG (Data Pair) FPE - Foam Polyethylene
Insulation Resistance: 10000 Mega-Ohm
Lay Length: 2.0 in.
Pair Color Code Chart:
Number Color
1 (Power Pair) Brown & Blue
2 (Data Pair) Black & White
INNER SHIELD :
Inner Shield Material Trade Name: Beldfoil®
Inner Shield Type: Tape
Inner Shield Material: Aluminum Foil-Polyester Tape
Inner Shield % Coverage: 100 %
OUTER SHIELD :
Outer Shield Material: Unshielded
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG: 22
Outer Shield Drain Wire Stranding: 19x34
Outer Shield Drain Wire Conductor Material: TC - Tinned Copper
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .290 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -30°C To +80°C
Storage Temperature Range: -40°C To +80°C
UL Temperature Rating: 80°C (UL AWM Style 2464)
Bulk Cable Weight: 33 lbs/1000 ft.
Max. Recommended Pulling Tension: 47.5 lbs.
Min. Bend Radius (Install): 2.9 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CL2
CEC/C(UL) Specification: FT1
AWM Specification: UL Style 2464 (30 V 80°C) (I/II A)
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 10/01/2005
FLAME TEST :
UL Flame Test: UL1685 UL Loading
CSA Flame Test: FT1
PLENUM/NON-PLENUM :
Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS :
Unaveraged Impedance:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Unaveraged Impedance (Ω)
Data 120
Nom. Capacitance Conductor to Conductor:
Description Frequency (kHz) Start Frequency (kHz) Stop Frequency (kHz) Nom. Capacitance Conductor to Conductor (pF/ft)
Data 1 12.0
Nominal Velocity of Propagation:
Description Nominal Velocity of Propagation (%)
Data 76
Nom. Conductor DC Resistance @ 20 Deg. C: 17.5 Ω/1000 ft
Nominal Outer Shield DC Resistance @ 20 Deg. C: 7.9 Ω/1000 ft
Nom. Attenuation (dB/100 ft):
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
Data .125 .23
.500 .42
1.0 .60
Max. Operating Voltage - UL: 300 V RMS
Max. Recommended Current: 3 Amps per conductor @ 25°C
NOTES :
Notes: Micro Cable (Drop)
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
3087A U3R1000 #22 FS PR, #22 FS PR PVC 1000 41 GRAY U3R C
3087A U3R2000 #22 FS PR, #22 FS PR PVC 2000 84 GRAY U3R C
3087A U3R500 #22 FS PR, #22 FS PR PVC 500 19 GRAY U3R C
|
|
|