1332A | | Multi-Conductor - DataBus® ISA/SP-50 FOUNDATION Fieldbus or PROFIBUS Cable 20 pair, 18 AWG stranded (7x26) tinned copper conductors, polyolefin insulation, individual & overall Beldfoil® shield (100% coverage), tinned copper drain wire, oil-resistant PVC jacket. | |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 1332A 0031000 | 1,000 FT | 589.000 LB | ORANGE | C | 20 FS PR #18 PP FS FRPVC | 1332A 0031640 | 1,640 FT | 936.440 LB | ORANGE | C | 20 FS PR #18 PP FS FRPVC | 1332A 0061000 | 1,000 FT | 589.000 LB | BLUE, LIGHT | C | 20 FS PR #18 PP FS FRPVC | 1332A 0061640 | 1,640 FT | 936.440 LB | BLUE, LIGHT | C | 20 FS PR #18 PP FS FRPVC | |
Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs | AWG | Stranding | Conductor Material | Dia. (in.) | 20 | 18 | 7x26 | TC - Tinned Copper | .048 | |
Insulation
Insulation Material:
Insulation Material | PO - Polyolefin | |
Inner Shield
Inner Shield Material:
Inner Shield Trade Name | Type | Inner Shield Material | Coverage (%) | Beldfoil® | Tape | Aluminum Foil-Polyester Tape | 100 | |
Inner Shield Drain Wire AWG:
AWG | Stranding | Conductor Material | 20 | 7x28 | TC - Tinned Copper | |
Outer Shield
Outer Shield Material:
Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | Beldfoil® | Tape | Aluminum Foil-Polyester Tape | 100 | |
Outer Shield Drain Wire AWG:
AWG | Stranding | Drain Wire Conductor Material | 18 | 7x26 | TC - Tinned Copper | |
Outer Jacket
Outer Jacket Material:
Outer Jacket Material | PVC - Polyvinyl Chloride | |
Outer Jacket Ripcord: | Yes |
Overall Cabling
Overall Nominal Diameter: | 1.020 in. |
Pair
Pair Color Code Chart:
Number | Color | 1 | Blue & Orange Numbered 1 | 2 | Blue & Orange Numbered 2 | 3 | Blue & Orange Numbered 3 | 4 | Blue & Orange Numbered 4 | 5 | Blue & Orange Numbered 5 | 6 | Blue & Orange Numbered 6 | 7 | Blue & Orange Numbered 7 | 8 | Blue & Orange Numbered 8 | 9 | Blue & Orange Numbered 9 | 10 | Blue & Orange Numbered 10 | 11 | Blue & Orange Numbered 11 | 12 | Blue & Orange Numbered 12 | 13 | Blue & Orange Numbered 13 | 14 | Blue & Orange Numbered 14 | 15 | Blue & Orange Numbered 15 | 16 | Blue & Orange Numbered 16 | 17 | Blue & Orange Numbered 17 | 18 | Blue & Orange Numbered 18 | 19 | Blue & Orange Numbered 19 | 20 | Blue & Orange Numbered 20 | |
Pair Lay Length & Direction:
Lay Length (in.) | Twists/ft. (twist/ft) | 2.000 | 6.000 | |
Mechanical Characteristics (Overall)
Operating Temperature Range: | -30°C To +90°C |
UL Temperature Rating: | 90°C |
Max. Recommended Pulling Tension: | 1148 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 10.200 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
CEC/C(UL) Specification: | CMG |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 09/01/2006 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1685 FT4 Loading |
IEC Flame Test: | 60332-3-24 (Category C) |
Suitability
Suitability - Indoor: | Yes |
Suitability - Outdoor: | Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Unaveraged Impedance:
Description | Freq. (MHz) | Start Freq. (MHz) | Stop Freq. (MHz) | Impedance (Ohm) | | .03125 | | | 100 | |
Nom. Inductance:
Nom. Capacitance Conductor to Shield:
Nom. Mutual Capacitance:
Maximum Capacitance Unbalance:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 5.86 | |
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 4.9 | |
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: | 7.500 Ohm/1000 ft |
Nom. Attenuation:
Description | Freq. (MHz) | Start Freq. (MHz) | Stop Freq. (MHz) | Attenuation (dB/100 ft.) | | .039 | | | .08 | |
Max. Attenuation:
() | Freq. (MHz) | Attenuation (dB/100 ft.) | .091 | 0.039 | 0.091 | |
Max. Operating Voltage - UL:
Max. Recommended Current:
Description | Current | Per Conductor | 5.2 Amps | |
Other Electrical Characteristic 1: | Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft |
Other Electrical Characteristic 2: | 31.25 KBits/sec |